Clear-Com Communication Systems Page 68 of 100
Tempest 2400 Wireless Intercom System
Pairing with a Base Station
Pair Beltstation to Base Station:
Confirm that the base station is powered on and in Operational Mode (not
in Menu Mode) and that the beltstation is powered off. Confirm that the
base station’s Network Number and Lockout Key are adjusted as needed.
See the section on Set Network Number and Lockout Key on page 31.
Plug one end of the Pairing cable into the base station and the other end
into the beltstation.
The pairing cable is a standard 3.5mm
(1/8 in.) male to male stereo patch cord
.
Turn the beltstation power on by pressing and holding the beltstation Power ON/OFF button for two
seconds. The Pairing process will begin automatically. Watch for the message “Pairing Complete” to
appear briefly on the beltstation display. The beltstation will automatically re-initialize.
Adjust Beltstation Slot
The base station slot assignment only affects the order that the base station Operational screen displays
beltstation information when the base station is in the Static display mode. If the base station is routinely
used as a communication port or for monitoring beltstations, it may be more convenient to always have
the same user appear in the same position on the base station display. This is a personal preference
setting.
In the base station Tech menu, choose Static or Dynamic from the “Display Slot Assignments” screen.
‘Dynamic’ the default, will work without any adjustment, and always displays beltstations in alpha-numeric
order by name.
“Static” will be the preferred choice for users who want to ensure that a beltstation that is logged in will
always appears in the same location (slot) on the base station display and are using only one base
station. When selecting ‘Static’ slot assignments, you must also enter the Tech Menu for each beltstation
and assign each beltstation a different slot (1 – 5).
The base station default is for Dynamic Slot Assignment. This means that when beltstations log in to a
base, the information about the beltstations is displayed on the base station LCD screen in alpha-numeric
order according to the name of the beltstation-- “Dir” appears before “Light1”, which appears before
“StgMgr”, but they can change slots depending on which beltstations are turned on. If the default settings
are used, nothing is necessary. If the base station is located in an equipment room and is not routinely
used as a communication port or to manage beltstations, nothing is necessary.
Adjusting so that each beltstation always appears in the same position of the base station display is a two
step process:
1. Advance to the base station’s “Display Slot Assignment” section of the “Tech Menu” and select
“Static”.
2. In each beltstation, advance to the “Base Slot” section of the “Tech Menu” and adjust each
beltstation to a different slot (1 – 5). The beltstation designated to slot 1 will always appear on the
far left of the base station display, with slot 2 appearing in the next position to the right, and so on.
In “Static” mode, if a beltstation is not turned on, or is logged out due to being out of range, the base
station LCD will display a very obvious X, making it easy to see at a glance, which beltstations are