Clear-Com Communication Systems Page 35 of 100
Tempest 2400 Wireless Intercom System
GPO Relay Contacts
Tempest Wireless provides six General Purpose Output (GPO) contact closures. These GPO contact
closures can be used for interfacing with other external devices. The SA (Stage Announce) Relay and the
five GPO relays, one for each beltstation, are available through the DB-15 Relay Connector on the back
of the Tempest base station. These relays can be triggered from the wireless beltstations.
The Stage Announce Relay function in the Tempest base station is activated by the STAGE button. The
SA Relay remains closed as long as the Stage button is pressed.
The user can reassign the following beltstation buttons and features to control an individual relay uniquely
assigned to that beltstation: Talk A/B, Talk C/D, Ch A/B, Ch C/D, Stage, Enter, or Battery < 10%. The
relay is made when the assigned button is pressed and remains closed for as long as the button is
pressed.
The individual GPO relay can also be triggered by the low battery level alert of the beltstation. In this case
the relay is made when the battery level of the beltstation reaches 10% and remains closed until the
battery is replaced or the beltstation is turned off.
All relay contacts can support 1 Amp at 30 VDC.
The relay completes a circuit. Tempest does not supply any power to the circuit.
Since every user will require a custom application, cables for your RELAY connections will require some
bench work.
DB-15 Relay Wiring
Pin Pin
1 Relay 1 9 Relay 1
2 Relay 2 10 Relay 2
3 Relay 3 11 Relay 3
4 Relay 4 12 Relay 4
5 Relay 5 13 Relay 5
6 Relay SA 14 Relay SA
7 Not Used 15 Not Used
8 Not Used
Tempest DB-15 Connector